German precision and excellence

NX30 - Naxis
NX30 - Naxis
NX30 - Naxis
PLATFORM SWITCHING

Preserve alveolar bone levels around implant

NX30 - Naxis
MICRO THREAD

Faster regeneration, shorter recovery time with Micro threads, reduces the risk of infection penetration to the bone

NX30 - Naxis
INTERMEDIATE THREAD

Sigma design implant threads. Allows a reliable stability on corticospongioid level

The Micro Porous Surface
The Micro Porous Surface
The Micro Porous Surface

more surface roughness, more osseointegration

from German engineers

MPS surface is produced with the Sandblasted, large grit, acid-etched implant surface (SLA)

Discover now
NX30 - Naxis
IMPLANT BODY

Precision of German engineering on surgical parts. Fully compatible drill bits with the implants shape for high initial stability

NX30 - Naxis
NX30 - Naxis
ACTIVE THREAD

Multiple levels of height on threads which allows enlarging the surface of the implant. Allows Achieving reliable initial stability in soft bone

NX30 - Naxis
ANTIROTATIONAL CANAL

Deep canal on implant body prevents release of implant

NX30 - Naxis
APICAL PART

Curved tip! Reduces the risk on the perforation of the Schneider’s membrane

NX30 - Naxis
NX30 - Naxis

2.1 mm inner diameter and 11 degree conical connection width.

NX30 - Naxis
Package

A sterile implant with cover screw in double tube system

Package
NX30 - Naxis
Implant included
NX30 - Naxis
Implant closure screw included

DIAMETER

3.25mm

6mm

8mm

10mm

11,5mm

13mm

DIAMETER

3.75mm

6mm

8mm

10mm

11,5mm

13mm

DIAMETER

4.2mm

6mm

8mm

10mm

11,5mm

13mm

DIAMETER

5.0mm

6mm

8mm

10mm

11,5mm

13mm

Surgical Guide
Select Bone Type
FOR JUST 3.25mm

Bone type I and II no need the use 3,0 final drill instead use 3.2 countersink for In bone type 3 and 4 case, use 3.0 finishing drill and 3.2 countersink

FOR JUST 3.75mm

Bone type I and II no need the use 3,0 final drill instead use 3.2 countersink for In bone type 3 and 4 case, use 3.0 finishing drill and 3.2 countersink

FOR JUST 4.2mm

Bone type I and II no need the use 3,0 final drill instead use 3.2 countersink for In bone type 3 and 4 case, use 3.0 finishing drill and 3.2 countersink

FOR JUST 5.0mm

Bone type I and II no need the use 3,0 final drill instead use 3.2 countersink for In bone type 3 and 4 case, use 3.0 finishing drill and 3.2 countersink

FOR JUST 3.25mm

Bone type I and II no need the use 3,0 final drill instead use 3.2 countersink for In bone type 3 and 4 case, use 3.0 finishing drill and 3.2 countersink

Documents

Implant Surgical Guide Download Surgical Guide
IFU for Suprastructure Download e-IFU
Implant Prospectus Download e-IFU